Inverter Parameter Table |
Model: | NKH-5KW | NKH-10KW |
Rated Power | 5000W | 10000W |
Mains Input | Rated Input Voltage (Settable) | 208VAC/220VAC/230VAC/240VAC |
Mains Supply Input Voltage Range | 170-280VAC; 90-280VAC |
Mains Supply Input Frequency | 50Hz/60Hz(Auto detection) |
Output | Rated Output Voltage (settable) | 208VAC/220VAC/230VAC/240VAC ±5% |
Surge Power | 20000VA |
Efficiency | 94% |
Switching Time | 10ms |
Overload power | 1min@102%-110% Load, 10s@110%-l30% Load, 3s@130%-150% Load,0.2s@> 150% Load |
Battery And AC Charging | Battery Voltage Rating | 51.2VDC |
Floating Charge Voltage | 54VDC |
Overcharge Protection | 64VDC |
Maximum Charging Current | 80A | 160A |
PV Charging | Maximum PV Array Power | PV 5500w | 1 way PV 5500w; 2 way PV 5500w |
MPPT Range Operating Voltage | 120-430VDC |
Maximum PV Array Open Circuit Voltage | 450VDC |
Maximum Charge Current | 80A | 160A |
Maximum Efficiency | 98% |
Mains Supply And PV Charging | Mains Supply and PV charging Maximum | 80A | 160A |
charging current (AC charger plus PV charger) |
Basic Specifications | Communication Interface | vUSB/RS232/GPRS/WIFI |
Working Environment | Humidity | 5% to 95% relative humidity(non-condensing) |
Operating Temperature Range | 0°C-55°C |
Storage Temperature | -15°C-60°C |
Dimension (L*W*H) | 770*410*222.5mm | 930*410*222.5mm |