Availability: | |
---|---|
SN Single-phase IGBT Low Frequency Inverter
SNAT
MAIN FEATURES
◆High reliability Frequency tracking, noise filtering and low distortion in inverter output because of double-conversion design
◆High adaptability A wide range of input frequency, which realizes stable operation of fuel generators
◆High optimal performance of the battery An intelligent battery management technology, which guarantees a longer battery life and decreases the times of battery maintenance
◆Overall and reliable protection A power-on test function, which can avoid the faults because of hazards of the inverter
◆Overall automatic protection and alarms such as output overload protection
◆Efficient IGBT (Insulated Gate Bipolar Transistor) inversion technology Good high-speed switching feature, large-voltage and large-current operating characteristics, and voltage drive of IGBT (The fifth-generation IGBT has a lower saturation voltage drop and higher operation efficiency and reliability.)
Product Specifications | ||||||||
Modle:SN- | 6KW | 8KW | 10KW | 12KW | 15KW | 20KW | 30KW | |
Rated Power | 6KW | 8KW | 10KW | 12KW | 15KW | 20KW | 30KW | |
Battery | Rated Voltage | 96VDC/192VDC | 192VDC | |||||
Charge Current | 10A-20A | |||||||
Low Voltage Protection | 84VDC/168VDC | 168VDC | ||||||
Input | Voltage Range | 88-132VAC/176-264VAC | ||||||
Frequency | 45-65Hz | |||||||
Output | Voltage Range | 110VAC/220VAC; ±5%( Inversion mode) | ||||||
Frequency | 50/60Hz± 1 %( Inversion mode) | |||||||
Output Wave | Pure Sine Wave | |||||||
Conversion Time | < 10ms(Typical load) | |||||||
Efficiency | >85% (100% Resistive Load) | >90% (100% Resistive Load) | ||||||
Overload | 110-120%/30S; >160%/300ms; | |||||||
Protection Function | Battery overvoltage protection, battery undervoltage protection, overload,protection, short circuit protection, overtemperature protection, etc. | |||||||
Operation Of Ambient Temperature | 0-40°C | |||||||
Ambient Temperature For Storage | -15-+50°C | |||||||
Operation/Storage Ambient | 0-90% No Condensation | |||||||
Product Dimensions:DxWxH(mm) | 638*260*750 | 690*370*810 | 740*720*1340 | |||||
Gross Weight (KG) | 80 | 90 | 110 | 130 | 150 | 170 | 227 |
MAIN FEATURES
◆High reliability Frequency tracking, noise filtering and low distortion in inverter output because of double-conversion design
◆High adaptability A wide range of input frequency, which realizes stable operation of fuel generators
◆High optimal performance of the battery An intelligent battery management technology, which guarantees a longer battery life and decreases the times of battery maintenance
◆Overall and reliable protection A power-on test function, which can avoid the faults because of hazards of the inverter
◆Overall automatic protection and alarms such as output overload protection
◆Efficient IGBT (Insulated Gate Bipolar Transistor) inversion technology Good high-speed switching feature, large-voltage and large-current operating characteristics, and voltage drive of IGBT (The fifth-generation IGBT has a lower saturation voltage drop and higher operation efficiency and reliability.)
Product Specifications | ||||||||
Modle:SN- | 6KW | 8KW | 10KW | 12KW | 15KW | 20KW | 30KW | |
Rated Power | 6KW | 8KW | 10KW | 12KW | 15KW | 20KW | 30KW | |
Battery | Rated Voltage | 96VDC/192VDC | 192VDC | |||||
Charge Current | 10A-20A | |||||||
Low Voltage Protection | 84VDC/168VDC | 168VDC | ||||||
Input | Voltage Range | 88-132VAC/176-264VAC | ||||||
Frequency | 45-65Hz | |||||||
Output | Voltage Range | 110VAC/220VAC; ±5%( Inversion mode) | ||||||
Frequency | 50/60Hz± 1 %( Inversion mode) | |||||||
Output Wave | Pure Sine Wave | |||||||
Conversion Time | < 10ms(Typical load) | |||||||
Efficiency | >85% (100% Resistive Load) | >90% (100% Resistive Load) | ||||||
Overload | 110-120%/30S; >160%/300ms; | |||||||
Protection Function | Battery overvoltage protection, battery undervoltage protection, overload,protection, short circuit protection, overtemperature protection, etc. | |||||||
Operation Of Ambient Temperature | 0-40°C | |||||||
Ambient Temperature For Storage | -15-+50°C | |||||||
Operation/Storage Ambient | 0-90% No Condensation | |||||||
Product Dimensions:DxWxH(mm) | 638*260*750 | 690*370*810 | 740*720*1340 | |||||
Gross Weight (KG) | 80 | 90 | 110 | 130 | 150 | 170 | 227 |